中文字幕一区二区5566_av自拍网站观看_夜晚在线免费观看黄色AV_狼人香蕉香蕉在线28

TLS-C5

 

TLS-C5 charger can be used more than 4kw inverter power supply with intelligent charging 

management. CPU automatic control of the whole process, according to the battery to charge 

different capacity to make safer and more efficient charging. Adopting temperature 

compensation technology, according to changes in temperature to control the charging current 

size, can effectively maintain the battery inside the active substance, both to ensure the 

charging maximum activation of battery charging time savings in battery capacity saturation 

CPU to take intermittent charging mode to extend battery life. 

Features:

● New three-stage charging algorithm 

● CPU whole process automatic control

● Intelligent Charge management Mode

● LED indication 

● input overvoltage,under voltage, over current, over temperature protection environment 

● energy saving design 

 

 

  

Datasheet
Module   TLS-C5
DC input vtg 192V/324V/492V
output current  0-5A
DC output vtg  ±10%
battery speed charge current:0.1C,peak charge current:0.2C
Input vtg & frequency 185260VAC;4763HZ
Ripple vtg ≤800mv
Efficiency input 220VAC full load ≥90%
Over temperature protection ≥85 degree C, then shut down automatically
discharge current 0.25mA
Temperature factor ±0.03%/degree C(0-50degree C)
Cooling  fan inside
Anti-shock 10500Hz.2G 10min every cycle,last 60 minutes,各軸
Isolation&anti-pressure 1500v (1minute) among input,output and shell
Isolation resistance 500vdc/100MΩ among input,output and shell
Working temperature,humidity -20℃~+60,Non-condensate20%-95%RH
LED indication indicates constant currentconstant voltage、floating charge accident
size 123*240*64mm
Weight 1.6kg
Standard GB17945-2010

 

PDF Download